Skip to content

Cart

Your cart is empty

Full Technical Test Data

ALONEFIRE SV003 365nm

Full published measurement and product information from our UV flashlight testing record.

ALONEFIRE SV003 365nm
Brand ALONEFIRE
Model SV003 365nm
Sample ID #UV-004
Wavelength 365nm
Filter Status ZWB2 Filter
Battery Type 18650 x1
Test Status Completed
Amazon Price $24.99
ASIN B07SWW5FHB
FNSKU / Amazon Barcode X0027FZZD9

Continuous Output Results

Published output, retention, and runtime values from the continuous-output test record.

UV Geek UV Energy Index

42

Output Retained — 10 Min

60%

Output Retained — 30 Min

60%

Continuous Operating Time

3 hr 8 min

Power Curve

ALONEFIRE SV003 365nm

UV Irradiance at Distance

UV irradiance measurements are shown in µW/cm².

Distance UV Irradiance
10 ft 28 µW/cm²
20 ft
30 ft
40 ft
50 ft
60 ft

Amazon Product Record

Amazon Price $24.99
ASIN B07SWW5FHB
FNSKU / Amazon Barcode X0027FZZD9
Amazon Product URL Open Amazon Listing →

Exact Amazon Listing Name

ALONEFIRE SV003 10W 365nm UV Flashlight Portable USB Rechargeable Woods Lamp Black Light for Pet Urine Detection, Resin Curing, Scorpion, Fishing, Minerals, Cure Glue, Bed Bugs with Battery, Charger

How UV Geek UV Energy Index Is Calculated

During the continuous-output test, the Linshang LS128 measures cumulative UV energy density. The instrument reports accumulated energy in millijoules per square centimeter (mJ/cm²).

UV Geek UV Energy Index = LS128 Total Energy (mJ/cm²) ÷ 1,000

Dividing by 1,000 converts the cumulative energy density from mJ/cm² to J/cm². The resulting numerical value is rounded to the nearest whole number and reported as the UV Geek UV Energy Index.

Calculation for this tested flashlight

41590 mJ/cm² ÷ 1,000 = 41.59 J/cm²

UV Geek UV Energy Index = 42

The UV Geek UV Energy Index is a derived comparison metric, not an industry-standard unit of measurement. It should not be confused with instantaneous UV irradiance measurements such as µW/cm².

Testing was conducted by UV Geek using consistent, documented procedures and factory-calibrated measurement equipment. Published results and derived metrics reflect the specific units tested, the recorded measurements, and UV Geek’s interpretation of those data.