Skip to content

Cart

Your cart is empty

Full Technical Test Data

ALONEFIRE SV43 365nm

Full published measurement and product information from our UV flashlight testing record.

ALONEFIRE SV43 365nm
Brand ALONEFIRE
Model SV43 365nm
Sample ID #UV-003
Wavelength 365nm
Filter Status ZWB2 Filter
Battery Type 21700 x1
Test Status Completed
Amazon Price $56.99
ASIN B09HH3KZ6P
FNSKU / Amazon Barcode X00319IC7L

Continuous Output Results

Published output, retention, and runtime values from the continuous-output test record.

UV Geek UV Energy Index

105

Output Retained — 10 Min

45%

Output Retained — 30 Min

38%

Continuous Operating Time

2 hr 47 min

Power Curve

ALONEFIRE SV43 365nm

UV Irradiance at Distance

UV irradiance measurements are shown in µW/cm².

Distance UV Irradiance
10 ft 73 µW/cm²
20 ft 25 µW/cm²
30 ft 11 µW/cm²
40 ft 6 µW/cm²
50 ft 2 µW/cm²
60 ft 0 µW/cm²

Amazon Product Record

Amazon Price $56.99
ASIN B09HH3KZ6P
FNSKU / Amazon Barcode X00319IC7L
Amazon Product URL Open Amazon Listing →

Exact Amazon Listing Name

ALONEFIRE SV43 36W 365nm UV Flashlight USB C Rechargeable Ultraviolet Black Light Woods Lamp for Pet Urine Detector, Resin Curing, Scorpion, Fishing, Leak with UV Protective Glasses, Battery

How UV Geek UV Energy Index Is Calculated

During the continuous-output test, the Linshang LS128 measures cumulative UV energy density. The instrument reports accumulated energy in millijoules per square centimeter (mJ/cm²).

UV Geek UV Energy Index = LS128 Total Energy (mJ/cm²) ÷ 1,000

Dividing by 1,000 converts the cumulative energy density from mJ/cm² to J/cm². The resulting numerical value is rounded to the nearest whole number and reported as the UV Geek UV Energy Index.

Calculation for this tested flashlight

105114 mJ/cm² ÷ 1,000 = 105.114 J/cm²

UV Geek UV Energy Index = 105

The UV Geek UV Energy Index is a derived comparison metric, not an industry-standard unit of measurement. It should not be confused with instantaneous UV irradiance measurements such as µW/cm².

Testing was conducted by UV Geek using consistent, documented procedures and factory-calibrated measurement equipment. Published results and derived metrics reflect the specific units tested, the recorded measurements, and UV Geek’s interpretation of those data.