Skip to content

Cart

Your cart is empty

Full Technical Test Data

DARKBEAM Dual 365-395nm

Full published measurement and product information from our UV flashlight testing record.

DARKBEAM Dual 365-395nm
Brand DARKBEAM
Model Dual 365-395nm
Sample ID #UV-013-395
Wavelength 395nm
Filter Status Not Filtered
Battery Type 21700 x1
Test Status Completed
Amazon Price $19.99
ASIN B0FCM8N9TP
FNSKU / Amazon Barcode XOO4PZMW67

Continuous Output Results

Published output, retention, and runtime values from the continuous-output test record.

UV Geek UV Energy Index

5

Output Retained — 10 Min

0%

Output Retained — 30 Min

0%

Continuous Operating Time

12+ hr

Power Curve

DARKBEAM Dual 365-395nm

UV Irradiance at Distance

UV irradiance measurements are shown in µW/cm².

Distance UV Irradiance
10 ft 19 µW/cm²
20 ft
30 ft
40 ft
50 ft
60 ft

Amazon Product Record

Amazon Price $19.99
ASIN B0FCM8N9TP
FNSKU / Amazon Barcode XOO4PZMW67
Amazon Product URL Open Amazon Listing →

Exact Amazon Listing Name

DARKBEAM UV Flashlight 365nm & 395nm Dual Black Light Woods Lamp Ringworm | 365 395 nm Blacklight Flashlights, Rechargeable LED Ultraviolet Powerful, for Pet Urine, Uranium Glass, Rocks, Resin Curing

How UV Geek UV Energy Index Is Calculated

During the continuous-output test, the Linshang LS128 measures cumulative UV energy density. The instrument reports accumulated energy in millijoules per square centimeter (mJ/cm²).

UV Geek UV Energy Index = LS128 Total Energy (mJ/cm²) ÷ 1,000

Dividing by 1,000 converts the cumulative energy density from mJ/cm² to J/cm². The resulting numerical value is rounded to the nearest whole number and reported as the UV Geek UV Energy Index.

Calculation for this tested flashlight

4736 mJ/cm² ÷ 1,000 = 4.736 J/cm²

UV Geek UV Energy Index = 5

The UV Geek UV Energy Index is a derived comparison metric, not an industry-standard unit of measurement. It should not be confused with instantaneous UV irradiance measurements such as µW/cm².

Testing was conducted by UV Geek using consistent, documented procedures and factory-calibrated measurement equipment. Published results and derived metrics reflect the specific units tested, the recorded measurements, and UV Geek’s interpretation of those data.