Skip to content

Cart

Your cart is empty

Full Technical Test Data

DARKBEAM Mini 395nm

Full published measurement and product information from our UV flashlight testing record.

DARKBEAM Mini 395nm
Brand DARKBEAM
Model Mini 395nm
Sample ID #UV-009
Wavelength 395nm
Filter Status Not Filtered
Battery Type Built-in rechargeable Li-ion
Test Status Completed
Amazon Price $11.99
ASIN B0CCDPDB9H
FNSKU / Amazon Barcode X003WMXQ6T

Continuous Output Results

Published output, retention, and runtime values from the continuous-output test record.

UV Geek UV Energy Index

228

Output Retained — 10 Min

97%

Output Retained — 30 Min

86%

Continuous Operating Time

12+ hr

Power Curve

DARKBEAM Mini 395nm

UV Irradiance at Distance

UV irradiance measurements are shown in µW/cm².

Distance UV Irradiance
10 ft 267 µW/cm²
20 ft 73 µW/cm²
30 ft 36 µW/cm²
40 ft 19 µW/cm²
50 ft 10 µW/cm²
60 ft 9 µW/cm²

Amazon Product Record

Amazon Price $11.99
ASIN B0CCDPDB9H
FNSKU / Amazon Barcode X003WMXQ6T
Amazon Product URL Open Amazon Listing →

Exact Amazon Listing Name

DARKBEAM Flashlight UV Black Light 395 NM, Mini but Powerful USB- C | LED Rechargeable Woods Lamp, Ultraviolet Flashlights for Pet Dog Urine, Stains Detection / Resin Curing / Fluorescent Agent

How UV Geek UV Energy Index Is Calculated

During the continuous-output test, the Linshang LS128 measures cumulative UV energy density. The instrument reports accumulated energy in millijoules per square centimeter (mJ/cm²).

UV Geek UV Energy Index = LS128 Total Energy (mJ/cm²) ÷ 1,000

Dividing by 1,000 converts the cumulative energy density from mJ/cm² to J/cm². The resulting numerical value is rounded to the nearest whole number and reported as the UV Geek UV Energy Index.

Calculation for this tested flashlight

228374 mJ/cm² ÷ 1,000 = 228.374 J/cm²

UV Geek UV Energy Index = 228

The UV Geek UV Energy Index is a derived comparison metric, not an industry-standard unit of measurement. It should not be confused with instantaneous UV irradiance measurements such as µW/cm².

Testing was conducted by UV Geek using consistent, documented procedures and factory-calibrated measurement equipment. Published results and derived metrics reflect the specific units tested, the recorded measurements, and UV Geek’s interpretation of those data.