Skip to content

Cart

Your cart is empty

Full Technical Test Data

ESCO LITE E51 395nm

Full published measurement and product information from our UV flashlight testing record.

ESCO LITE E51 395nm
Brand ESCO LITE
Model E51 395nm
Sample ID #UV-027
Wavelength 395nm
Filter Status Not Filtered
Battery Type AA x3
Test Status Completed
Amazon Price $12.99
ASIN B008133KB4
FNSKU / Amazon Barcode X0001KDE29

Continuous Output Results

Published output, retention, and runtime values from the continuous-output test record.

UV Geek UV Energy Index

72

Output Retained — 10 Min

55%

Output Retained — 30 Min

43%

Continuous Operating Time

12+ hr

Power Curve

ESCO LITE E51 395nm

UV Irradiance at Distance

UV irradiance measurements are shown in µW/cm².

Distance UV Irradiance
10 ft 54 µW/cm²
20 ft
30 ft
40 ft
50 ft
60 ft

Amazon Product Record

Amazon Price $12.99
ASIN B008133KB4
FNSKU / Amazon Barcode X0001KDE29
Amazon Product URL Open Amazon Listing →

Exact Amazon Listing Name

ESCO LITE Black Light for Pet Urine Detection UV Flashlight 395nm Pet Urine Detector Light for Cat Pee and Dog Stains Carpets Floors

How UV Geek UV Energy Index Is Calculated

During the continuous-output test, the Linshang LS128 measures cumulative UV energy density. The instrument reports accumulated energy in millijoules per square centimeter (mJ/cm²).

UV Geek UV Energy Index = LS128 Total Energy (mJ/cm²) ÷ 1,000

Dividing by 1,000 converts the cumulative energy density from mJ/cm² to J/cm². The resulting numerical value is rounded to the nearest whole number and reported as the UV Geek UV Energy Index.

Calculation for this tested flashlight

72065 mJ/cm² ÷ 1,000 = 72.065 J/cm²

UV Geek UV Energy Index = 72

The UV Geek UV Energy Index is a derived comparison metric, not an industry-standard unit of measurement. It should not be confused with instantaneous UV irradiance measurements such as µW/cm².

Testing was conducted by UV Geek using consistent, documented procedures and factory-calibrated measurement equipment. Published results and derived metrics reflect the specific units tested, the recorded measurements, and UV Geek’s interpretation of those data.