Full Technical Test Data

GOREIT G1979 LCD 365nm

Full published measurement and product information from our UV flashlight testing record.

GOREIT G1979 LCD 365nm
Brand GOREIT
Model G1979 LCD 365nm
Sample ID #UV-008
Wavelength 365nm
Filter Status ZWB2 Filter
Battery Type 26650 x1
Test Status Completed
Amazon Price $32.99
ASIN B0G5MDWDNF
FNSKU / Amazon Barcode

Continuous Output Results

Published output, retention, and runtime values from the continuous-output test record.

UV Geek UV Energy Index

121

Output Retained — 10 Min

45%

Output Retained — 30 Min

42%

Continuous Operating Time

3 hr 44 min

Power Curve

GOREIT G1979 LCD 365nm

UV Irradiance at Distance

UV irradiance measurements are shown in µW/cm².

Distance UV Irradiance
10 ft 165 µW/cm²
20 ft 47 µW/cm²
30 ft 19 µW/cm²
40 ft 11 µW/cm²
50 ft 7 µW/cm²
60 ft 4 µW/cm²

Amazon Product Record

Amazon Price $32.99
ASIN B0G5MDWDNF
FNSKU / Amazon Barcode
Amazon Product URL Open Amazon Listing →

Exact Amazon Listing Name

365nm Black Light UV Flashlight Rechargeable with Filter Lens & LCD Display | 30w Professional Blacklight, USB Charging, for Pet Urine Detection, Cleaning, Resin Curing, Rocks, Scorpion, Blood Tracking

How UV Geek UV Energy Index Is Calculated

During the continuous-output test, the Linshang LS128 measures cumulative UV energy density. The instrument reports accumulated energy in millijoules per square centimeter (mJ/cm²).

UV Geek UV Energy Index = LS128 Total Energy (mJ/cm²) ÷ 1,000

Dividing by 1,000 converts the cumulative energy density from mJ/cm² to J/cm². The resulting numerical value is rounded to the nearest whole number and reported as the UV Geek UV Energy Index.

Calculation for this tested flashlight

120516 mJ/cm² ÷ 1,000 = 120.516 J/cm²

UV Geek UV Energy Index = 121

The UV Geek UV Energy Index is a derived comparison metric, not an industry-standard unit of measurement. It should not be confused with instantaneous UV irradiance measurements such as µW/cm².

Testing was conducted by UV Geek using consistent, documented procedures and factory-calibrated measurement equipment. Published results and derived metrics reflect the specific units tested, the recorded measurements, and UV Geek’s interpretation of those data.