Skip to content

Cart

Your cart is empty

Full Technical Test Data

LEPRO 395nm Black Light

Full published measurement and product information from our UV flashlight testing record.

LEPRO 395nm Black Light
Brand LEPRO
Model 395nm Black Light
Sample ID #UV-023
Wavelength 395nm
Filter Status Not Filtered
Battery Type AAA x3
Test Status Completed
Amazon Price $8.99
ASIN B00GU55270
FNSKU / Amazon Barcode 4897033167734

Continuous Output Results

Published output, retention, and runtime values from the continuous-output test record.

UV Geek UV Energy Index

35

Output Retained — 10 Min

56%

Output Retained — 30 Min

53%

Continuous Operating Time

12+ hr

Power Curve

LEPRO 395nm Black Light

UV Irradiance at Distance

UV irradiance measurements are shown in µW/cm².

Distance UV Irradiance
10 ft 23 µW/cm²
20 ft
30 ft
40 ft
50 ft
60 ft

Amazon Product Record

Amazon Price $8.99
ASIN B00GU55270
FNSKU / Amazon Barcode 4897033167734
Amazon Product URL Open Amazon Listing →

Exact Amazon Listing Name

Lepro Lighting Ever UV LED Flashlight, 9 LED 395nm Blacklight Detector | Blacklight Detector for Pet Urine, Stain, Bed Bugs and More, 3 AAA Batteries Included

How UV Geek UV Energy Index Is Calculated

During the continuous-output test, the Linshang LS128 measures cumulative UV energy density. The instrument reports accumulated energy in millijoules per square centimeter (mJ/cm²).

UV Geek UV Energy Index = LS128 Total Energy (mJ/cm²) ÷ 1,000

Dividing by 1,000 converts the cumulative energy density from mJ/cm² to J/cm². The resulting numerical value is rounded to the nearest whole number and reported as the UV Geek UV Energy Index.

Calculation for this tested flashlight

34885 mJ/cm² ÷ 1,000 = 34.885 J/cm²

UV Geek UV Energy Index = 35

The UV Geek UV Energy Index is a derived comparison metric, not an industry-standard unit of measurement. It should not be confused with instantaneous UV irradiance measurements such as µW/cm².

Testing was conducted by UV Geek using consistent, documented procedures and factory-calibrated measurement equipment. Published results and derived metrics reflect the specific units tested, the recorded measurements, and UV Geek’s interpretation of those data.