Skip to content

Cart

Your cart is empty

Full Technical Test Data

TrixHub TH007 LCD 365nm

Full published measurement and product information from our UV flashlight testing record.

TrixHub TH007 LCD 365nm
Brand TrixHub
Model TH007 LCD 365nm
Sample ID #UV-010
Wavelength 365nm
Filter Status ZWB2 Filter
Battery Type 18650 x1
Test Status Completed
Amazon Price $15.63
ASIN B0F9W34NXC
FNSKU / Amazon Barcode X004P6CRMF

Continuous Output Results

Published output, retention, and runtime values from the continuous-output test record.

UV Geek UV Energy Index

32

Output Retained — 10 Min

46%

Output Retained — 30 Min

46%

Continuous Operating Time

3 hr 52 min

Power Curve

TrixHub TH007 LCD 365nm

UV Irradiance at Distance

UV irradiance measurements are shown in µW/cm².

Distance UV Irradiance
10 ft 32 µW/cm²
20 ft
30 ft
40 ft
50 ft
60 ft

Amazon Product Record

Amazon Price $15.63
ASIN B0F9W34NXC
FNSKU / Amazon Barcode X004P6CRMF
Amazon Product URL Open Amazon Listing →

Exact Amazon Listing Name

TrixHub 365nm Black Light UV Light Flashlight Rechargeable with LCD Display | Powerful Ultraviolet Lights for Pet Urine Detection, Resin Curing, Rockhounding, Scorpion, Uranium Glass, A/CLeak

How UV Geek UV Energy Index Is Calculated

During the continuous-output test, the Linshang LS128 measures cumulative UV energy density. The instrument reports accumulated energy in millijoules per square centimeter (mJ/cm²).

UV Geek UV Energy Index = LS128 Total Energy (mJ/cm²) ÷ 1,000

Dividing by 1,000 converts the cumulative energy density from mJ/cm² to J/cm². The resulting numerical value is rounded to the nearest whole number and reported as the UV Geek UV Energy Index.

Calculation for this tested flashlight

32126 mJ/cm² ÷ 1,000 = 32.126 J/cm²

UV Geek UV Energy Index = 32

The UV Geek UV Energy Index is a derived comparison metric, not an industry-standard unit of measurement. It should not be confused with instantaneous UV irradiance measurements such as µW/cm².

Testing was conducted by UV Geek using consistent, documented procedures and factory-calibrated measurement equipment. Published results and derived metrics reflect the specific units tested, the recorded measurements, and UV Geek’s interpretation of those data.