Skip to content

Cart

Your cart is empty

Full Technical Test Data

UV Beast 100 LED 385-395nm

Full published measurement and product information from our UV flashlight testing record.

UV Beast 100 LED 385-395nm
Brand UV Beast
Model 100 LED 385-395nm
Sample ID #UV-019
Wavelength 385-395nm
Filter Status Not Filtered
Battery Type AAA x6
Test Status Completed
Amazon Price $29.99
ASIN B01CV24OGK
FNSKU / Amazon Barcode X0012ZGOQ7

Continuous Output Results

Published output, retention, and runtime values from the continuous-output test record.

UV Geek UV Energy Index

61

Output Retained — 10 Min

60%

Output Retained — 30 Min

54%

Continuous Operating Time

12+ hr

Power Curve

UV Beast 100 LED 385-395nm

UV Irradiance at Distance

UV irradiance measurements are shown in µW/cm².

Distance UV Irradiance
10 ft 67 µW/cm²
20 ft
30 ft
40 ft
50 ft
60 ft

Amazon Product Record

Amazon Price $29.99
ASIN B01CV24OGK
FNSKU / Amazon Barcode X0012ZGOQ7
Amazon Product URL Open Amazon Listing →

Exact Amazon Listing Name

uvBeast V1 385-395nm Black Light UV Flashlight, High Power, 100 LED | 30-feet Flood Effect, Professional Grade, Commercial/Domestic Use, Works in Ambient Light, USA Stock, Engineered by uvBeast

How UV Geek UV Energy Index Is Calculated

During the continuous-output test, the Linshang LS128 measures cumulative UV energy density. The instrument reports accumulated energy in millijoules per square centimeter (mJ/cm²).

UV Geek UV Energy Index = LS128 Total Energy (mJ/cm²) ÷ 1,000

Dividing by 1,000 converts the cumulative energy density from mJ/cm² to J/cm². The resulting numerical value is rounded to the nearest whole number and reported as the UV Geek UV Energy Index.

Calculation for this tested flashlight

61344 mJ/cm² ÷ 1,000 = 61.344 J/cm²

UV Geek UV Energy Index = 61

The UV Geek UV Energy Index is a derived comparison metric, not an industry-standard unit of measurement. It should not be confused with instantaneous UV irradiance measurements such as µW/cm².

Testing was conducted by UV Geek using consistent, documented procedures and factory-calibrated measurement equipment. Published results and derived metrics reflect the specific units tested, the recorded measurements, and UV Geek’s interpretation of those data.