Skip to content

Cart

Your cart is empty

Full Technical Test Data

Vansky 12 LED 395nm

Full published measurement and product information from our UV flashlight testing record.

Vansky 12 LED 395nm
Brand Vansky
Model 12 LED 395nm
Sample ID #UV-025
Wavelength 395nm
Filter Status Not Filtered
Battery Type AAA x3
Test Status Completed
Amazon Price $7.99
ASIN B0758CJDGT
FNSKU / Amazon Barcode X001K58UIT

Continuous Output Results

Published output, retention, and runtime values from the continuous-output test record.

UV Geek UV Energy Index

18

Output Retained — 10 Min

68%

Output Retained — 30 Min

5%

Continuous Operating Time

12+ hr

Power Curve

Vansky 12 LED 395nm

UV Irradiance at Distance

UV irradiance measurements are shown in µW/cm².

Distance UV Irradiance
10 ft 13 µW/cm²
20 ft
30 ft
40 ft
50 ft
60 ft

Amazon Product Record

Amazon Price $7.99
ASIN B0758CJDGT
FNSKU / Amazon Barcode X001K58UIT
Amazon Product URL Open Amazon Listing →

Exact Amazon Listing Name

UV Light 395nm Blacklight Flashlight: Vansky 12 LED Black Light Mini Pet Urine Detection for Invisible Dog/Cat Dried Urine Stains on Carpet, Scorpion Finder, Resin Curing

How UV Geek UV Energy Index Is Calculated

During the continuous-output test, the Linshang LS128 measures cumulative UV energy density. The instrument reports accumulated energy in millijoules per square centimeter (mJ/cm²).

UV Geek UV Energy Index = LS128 Total Energy (mJ/cm²) ÷ 1,000

Dividing by 1,000 converts the cumulative energy density from mJ/cm² to J/cm². The resulting numerical value is rounded to the nearest whole number and reported as the UV Geek UV Energy Index.

Calculation for this tested flashlight

18411 mJ/cm² ÷ 1,000 = 18.411 J/cm²

UV Geek UV Energy Index = 18

The UV Geek UV Energy Index is a derived comparison metric, not an industry-standard unit of measurement. It should not be confused with instantaneous UV irradiance measurements such as µW/cm².

Testing was conducted by UV Geek using consistent, documented procedures and factory-calibrated measurement equipment. Published results and derived metrics reflect the specific units tested, the recorded measurements, and UV Geek’s interpretation of those data.